Series 211
Differential Pressure Transmitter
Data Sheet PDF Installation Manual PDFThe Series 211 Differential Pressure Transmitter can accurately measure positive, negative, or differential pressure and send the corresponding 4-20 mA output signal. The Series 211 is not position sensitive and can be mounted in any orientation without compromising accuracy. It also features a power LED, so you always know when the transmitter is operating. The compact, lightweight design makes installation simple and easy.
Specifications
- Maximum Pressure:
- Ranges ≤ 5 PSI -Max 15 PSI
Ranges > 5 PSI -Max 30 PSI - Media compatibility:
- Air and compatible non combustible, non corrosive gasses
- Accuracy:
- Ranges ≤ 4" w.c. 1.0%
Ranges ≥ 5" w.c. 0.25% - Temperature Ranges:
- Compensated: 15° to 120°F (-10° to 50°C)
Operating: -10° to 155°F (-25° to 70°C) - Thermal Effect:
- +/- 0.028% FS/°F
- Stability:
- +/- 0.25% FS/year
- Output Signal:
- 4-20 mA, 2-wire
- Loop Resistance:
- 250 Ω @ 24 VDC
- Power Supply:
- 12-30 VDC
- Housing Material:
- ABS Plastic
- Electrical Connections:
- screw terminals
- Process Connection:
- Push on connection for 1/8" I.D. tubing
Dimensional Drawing
Model Numbers
| Model Number | Pressure Range | Accuracy |
| 211-D001I-1 | 0 - 1 " | 1% |
| 211-D002I-1 | 0 - 2 " | 1% |
| 211-D004I-1 | 0 - 4 " | 1% |
| 211-D006I-3 | 0 - 6 " | 0.25% |
| 211-D010I-3 | 0 - 10 " | 0.25% |
| 211-D020I-3 | 0 - 20 " | 0.25% |
| 211-D040I-3 | 0 - 40 " | 0.25% |
| 211-D005P-3 | 0 - 5 PSI | 0.25% |
| 211-D010P-3 | 0 - 10 PSI | 0.25% |
| 211-D015P-3 | 0 - 15 PSI | 0.25% |
| 211-Z001I-1 | 0.5 –0 – 0.5” | 1% |
| 211-Z002I-1 | 1 –0 – 1” | 1% |
| 211-Z004I-1 | 2 –0 – 2” | 1% |
| 211-Z010I-3 | 5 –0 – 5” | 0.25% |